Alerify Datacenter - Notice history

Operational

Datacenter Power - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Datacenter Cooling - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Internet Circuits - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 98.76%
Apr 2026
May 2026
Jun 2026
Operational

Compute - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Storage - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Networking - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Website - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Phone System - Operational

100% - uptime
Apr 2026 · 100.0%May · 100.0%Jun · 100.0%
Apr 2026
May 2026
Jun 2026

Notice history

Jun 2026

Internet Circuit Issue
  • Resolved
    UTC
    Resolved
    This incident has been resolved.
  • Monitoring
    UTC
    Monitoring

    Our carrier partner has completed repair activities and is currently performing service validation and restoration verification. Connectivity appears to have been restored, and we are continuing to monitor the situation while final checks are completed. We will provide a final update once full service restoration has been confirmed.

  • Identified
    UTC
    Identified

    Repair activities are continuing as the carrier works to restore and stabilize the affected infrastructure. Connectivity has been restored and services are currently operating normally; however, the carrier remains engaged and monitoring the situation while additional remediation efforts are completed. No estimated time for full resolution is currently available.

  • Update
    UTC
    Update

    One of our upstream carrier providers is currently investigating an issue within their network. Field personnel have been dispatched to evaluate the affected infrastructure. No customer impact is currently being observed, and all services remain operational. We will continue to monitor the situation and provide updates as necessary.

  • Investigating
    UTC
    Investigating

    An issue has been detected with one of our internet circuits. All services are still online. Alerify is reaching out to the carrier to identify the cause of the problem. Updates will be provided when we have more information.

May 2026

Internet Circuit Issue
  • Postmortem
    UTC
    Postmortem

    On May 6, 2026, at approximately 10:54 AM EDT, DQE Communications began experiencing instability on an upstream transit connection, resulting in multiple rapid link state changes and routing session flapping. During this time, customers may have experienced intermittent connectivity, packet loss, or brief service outages across multiple locations.

     

    DQE Engineering immediately initiated an investigation and engaged the upstream provider for support. In response to the instability, the affected upstream port was administratively shut down at approximately 11:23 AM EDT to prevent further impact. To further protect overall network performance, DQE subsequently rerouted (drained) traffic away from the affected upstream path at approximately 12:10 PM EDT. Following these mitigation actions, customer services stabilized and no further widespread impact was observed.

     

    The issue was attributed to instability within an upstream transport path. The upstream provider advised that the event was related to a transient fiber disturbance in the Pittsburgh area impacting multiple services. No further detailed information has been made available at this time.

     

    All services have remained stable since mitigation actions were taken. DQE will continue to monitor network performance closely, and all related tickets will be placed under a 24-hour monitoring period to ensure continued stability.

  • Resolved
    UTC
    Resolved
    This incident has been resolved.
  • Monitoring
    UTC
    Monitoring

    Carrier has confirmed the circuit to be stable. We have put it back into service and will be monitoring it for the next few hours to ensure stability.

  • Identified
    UTC
    Identified

    The affected circuit has been removed from service until stability can be confirmed. We are also awaiting confirmation from the carrier regarding the root cause of the issue.

  • Investigating
    UTC
    Investigating

    An issue has been detected with one of our internet circuits. All services are still online. Alerify is reaching out to the carrier to identify the cause of the problem. Updates will be provided when we have more information.

Apr 2026

Apr 2026 to Jun 2026

Next